Twin
pumping unit, screwed design, with flages at both ends as
supply- and pressure units for oil supply per TRD 411 and TRD 604
as well as DIN 4755.
|

Picture I

Picture II
|
Components:
1.hp- Motot Pump with overflow valve
2.individual filter
2a lever controlled double filter
3.shutoff valve
4.pre-load option
5.mano-vakuum meter
6.manometer
7.check valve
8.overflow valve
9.oil pan
Accessories:
11 Leak detector Type HMW
12 electronic pressure switch S
13 dirt degree display E1, E2
|

BIK 5000/ 5-7
|

BIK 5000/ 8-10
|
Feeder
Unit (picture I and II) without backflow
|
|
Edition
with double filter (picture II
|
|
Connections
Suction / Pressure
Flange
|
Unit
Type
|
Discharge
at 1400min-¹
and 0 - 9 bar
L/h
|
Pump
Type
Series
VB
|
Motor
Power
KW
|
hp
Prod. No.
|
Dimensions
Length x width x height
|
|
hp
Prod. No.
|
|
|
Pipe
D 12 / o. FL
|
BIK
5000-1
|
45
|
VBP
|
0.12
|
052
0046
|
600x450
|
550
|
|
-.-
|
|
|
Pipe
D 12 / o. FL
|
BIK
5000-2
|
80
|
VBM
|
0.12
|
052
0047
|
600x450
|
550
|
|
-.-
|
|
|
Pipe
D 12 / o. FL
|
BIK
5000-3
|
120
|
VBG
|
0.12
|
052
0048
|
600x450
|
550
|
|
-.-
|
|
|
Pipe
D 12 / o. FL
|
BIK
5000-4
|
160
|
VBF
|
0.12
|
052
0049
|
600x450
|
550
|
|
-.-
|
|
|
DN
15 / DN 15
|
BIK
5000-5
|
300
|
VBGP
|
0.18
|
052
0050
|
600x450
|
550
|
|
052
0090
|
|
|
DN
15 / DN 15
|
BIK
5000-6
|
450
|
VBGM
|
0.25
|
052
0056
|
600x450
|
550
|
|
052
0091
|
|
|
DN
15 / DN 15
|
BIK
5000-7
|
600
|
VBGG
|
0.37
|
052
0057
|
600x450
|
550
|
|
052
0092
|
|
|
DN 25 / DN 25
|
BIK
5000-8
|
1000
|
VBHP
|
0.55
|
052
0058
|
800x600
|
700
|
|
052
0093
|
|
|
DN
25 / DN 25
|
BIK
5000-9
|
1500
|
VBHM
|
0.75
|
052
0059
|
800x600
|
700
|
|
052
0094
|
|
|
DN
25 / DN 25
|
BIK
5000-10
|
2000
|
VBHG
|
1.1
|
052
0060
|
800x600
|
700
|
|
052
0095
|
|
|
DN
32 / DN 32
|
BIK
5000-11
|
3000
|
VBHGP
|
1.5
|
052
0061
|
800x600
|
800
|
|
052
0096
|
|
|
DN
32 / DN 32
|
BIK
5000-12
|
4500
|
VBHGM
|
2.2
|
052
0062
|
800x600
|
800
|
|
052
0097
|
|
|
DN
40 / DN 40
|
BIK
5000-13
|
6000
|
VBHGG
|
3.0
|
052
0063
|
800x600
|
800
|
|
052
0098
|
|

|
1
|
hp-pump
with overflow valvel |
|
2
|
Filter |
|
3
|
Ball
valve |
|
4
|
Pre-filling |
|
5
|
Mano
vacuum meter |
|
6
|
Manometer |
|
7
|
Check
valve |
|
8
|
hp-overflow
valve |
|
9
|
Oil
pan |
|
12
|
Build
in pressure switch ,
or accessory "S" |
|
13
|
Pressure
pipe |
|
14
|
Suction
pipe |
|
15
|
Tank |
|
17
|
Filling
pipe |
|
18
|
Venting |
|
19
|
Backflow
pipe |
|
21
|
Circulation
unit |
|
22
|
check
valve, pre-pressure 1 bar |
|
23
|
Tank
with venting option ex.: manual or automatic through
swimmer valve |
|
24
|
Check
Valve |
|
30
|
Pressure
vent preset magnetic valve |
hp-closed
circular pipeline unit per DIN 4736 and DIN 4755, part 2 with overflow
valve (Pos.8) and return pipe to the thank. As single line
without overflow valve and return pipe. The single line
pressure is held through the adjustable overflow valve in
the pump.
|
1
|
hp-Pump
with overflow valve |
|
2
|
Filter
|
|
3
|
Ball
valve |
|
4
|
Manometer |
|
5
|
Vacuum
meter
|
|
6
|
Build
in pressure switch ,
or accessory "S" |
|
7
|
Pressure
vent preset magnetic valve |
|
8
|
hp-overflow
valve |
|
9
|
backflow
pipe |
|
10
|
circulation
unit |
|
11
|
valve |
|
13
|
preasure
pipe |
| 14 |
suction
pipe |
|
15
|
tank |
| 17 |
Filling
pipe |
| 18 |
Ventilation |
|
20
|
alternate
connector for backflow pipe to suction pipe for ground
pipe and septic tank. |
|
21
|
Tank
with venting option ex.: manual or automatic through
swimmer valve
|
|
22
|
check
valve, pre-pressure 1 bar |
|