Motor pump program and motor pump groups

hp TECHNIK Industrial Pumps

Just another WordPress site

Series VB; With integrated overflow valve

3.2

Series VB; With integrated overflow valve
Overflow Valves

Series VB; With integrated overflow valve

Single systems with 1400 min -1 and hp industrial pumps

Standard model:
A system up to 9 bar: Pressure stage 2 = 2 to 9 bar. Limited to a max. pressure of 6 bar as per DIN 4736. System up to 30 or 40 bar: Pressure stage 4 = 15 to 40 bar. Suitable for use with hydraulic oils, lubricating oils, all fuel oils, coal and lignite tar oils, kerosene and many other self-lubricating fluids. The motor output data applies for fluids with a viscosity of up to 80 cSt. From 80 to 150 cSt, the motor must be one power stage size stronger.
Available at a surcharge upon request.

The pump connections are indicated as follows:
A = suction connection
S = delivery connection

The standard models of the pumps are designed with a counterclockwise direction of
rotation (viewed from the pump shaft).
The position of the pump connections is independent of the direction of rotation.
(See illustration.)

Direction of rotation l = counterclockwise, standard model
For clockwise rotation, D, the oil connections A = suction and S = delivery are interchanged.

Series size Pump
type
Discharge at 1400 min -1 Motor Connections*
output
H1 Heater
Watt
Gear
rotor/shaft
Article-no.  
at 0 – 9 bar at 30 bar
SMG 1541 VBP 45 l/h 0,18 kW G 3/8“ 100 25/12 0350027 p max 9 bar
SMG 1542 VBM 80 l/h 0,18 kW G 3/8“ 100 25/12 0350028
SMG 1543 VBG 120 l/h 0,18 kW G 3/8“ 100 25/12 0350029
SMG 1544 VBF 160 l/h 0,18 kW G 3/8“ 100 25/12 0350030
SMG 1545 VBGP 300 l/h 0,18 kW G 1/2“ 100 38/12 0350031
SMG 1546 VBGM 450 l/h 0,37 kW G 1/2“ 100 38/12 0350032
SMG 1547 VBGG 600 l/h 0,37 kW G 1/2“ 100 38/12 0350033
SMG 1548 VBHP 1000 l/h 0,75 kW G 3/4“ 160 56/18 0350034
SMG 1549 VBHM 1500 l/h 0,75 kW G 3/4“ 160 56/18 0350035
SMG 1550 VBHG 2000 l/h 1,1 kW G 3/4“ 160 56/18 0350036
SMG 1551 VBHGP 3000 l/h 1,5 kW G 1“ 280 75/22 0350037
SMG 1552 VBHGM 4500 l/h 2,2 kW G 1“ 280 75/22 0350038
SMG 1553 VBHGG 6000 l/h 3,0 kW G 1“ 280 75/22 0350039
                   
SMG 1561 VBP 45 l/h 30 l/h 0,18 kW G 3/8“ 100 25/12 0350040 p max 30 bar
SMG 1562 VBM 80 l/h 60 l/h 0,18 kW G 3/8“ 100 25/12 0350041
SMG 1563 VBG 120 l/h 100 l/h 0,18 kW G 3/8“ 100 25/12 0350042
SMG 1564 VBF 160 l/h 140 l/h 0,37 kW G 3/8“ 100 25/12 0350043
SMG 1565 VBGP 300 l/h 240 l/h 0,37 kW G 1/2“ 100 38/12 0350044
SMG 1566 VBGM 450 l/h 390 l/h 0,75 kW G 1/2“ 100 38/12 0350045
SMG 1567 VBGG 600 l/h 540 l/h 0,75 kW G 1/2“ 100 38/12 0350046
SMG 1568 VBHP 1000 l/h 700 l/h 1,5 kW G 3/4“ 160 56/18 0350047
SMG 1569 VBHM 1500 l/h 1200 l/h 2,2 kW G 3/4“ 160 56/18 0350048
SMG 1570 VBHG 2000 l/h 1700 l/h 3,0 kW G 3/4“ 160 56/18 0350049
SMG 1571 VBHGP 3000 l/h 2200 l/h 4,0 kW G 1“ 280 75/22 0350050
SMG 1572 VBHGM 4500 l/h 3600 l/h 5,5 kW G 1“ 280 75/22 0350051
SMG 1573 VBHGG 6000 l/h 4800 l/h 7,5 kW G 1“ 280 75/22 0350052
Series size Pump

type

Discharge at 1400 min -1 Motor
output
connections* H1 Heater
Watt
Gear
rotor/shaft
Article-no.  
at 0 bar at 40 bar
SMG 1922 VBM 80 l/h 50 l/h 0,18 kW G 3/8“ 100 25/12 0390023 p max 40 bar
SMG 1923 VBG 120 l/h 80 l/h 0,37 kW G 3/8“ 100 25/12 0390024
SMG 1924 VBF 160 l/h 120 l/h 0,37 kW G 3/8“ 100 25/12 0390025
SMG 1925 VBGP 300 l/h 200 l/h 0,75 kW G 1/2“ 100 38/12 0390026
SMG 1926 VBGM 450 l/h 360 l/h 1,1 kW G 1/2“ 100 38/12 0390027
SMG 1927 VBGG 600 l/h 480 l/h 1,5 kW G 1/2“ 100 38/12 0390028
SMG 1928 VBHP 1000 l/h 600 l/h 2,2 kW G 3/4“ 160 56/18 0390029
SMG 1929 VBHM 1500 l/h 1000 l/h 3,0 kW G 3/4“ 160 56/18 0390030
SMG 1930 VBHG 2000 l/h 1400 l/h 4,0 kW G 3/4“ 160 56/18 0390031
SMG 1931 VBHGP 3000 l/h 2000 l/h 5,5 kW G 1“ 280 75/22 0390032
SMG 1932 VBHGM 4500 l/h 3200 l/h 7,5 kW G 1“ 280 75/22 0390033

*To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site! The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.

Series VB; With integrated overflow valve

Series
size
Pump
type
Discharge Motor output Dimensions
a a1 b c e1 f3 g g1 g2 h k k1 p s Pg
SMG 1541 VBP 45 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1542 VBM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1543 VBG 120 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1544 VBF 160 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1545 VBGP 300 l/h 0,18 kW 80 43 100 7 G 1/2“ 44 124 75 63 362 63 163 7 11
SMG 1546 VBGM 450 l/h 0,37 kW 90 43 112 7 G 1/2“ 44 139 75 71 390 69 180 7 11
SMG 1547 VBGG 600 l/h 0,37 kW 90 43 112 7 G 1/2“ 44 139 75 71 390 69 180 7 11
SMG 1548 VBHP 1000 l/h 0,75 kW 100 49 125 8 G 3/4“ 67 157 90 80 496 77 197 9,5 11
SMG 1549 VBHM 1500 l/h 0,75 kW 100 49 125 8 G 3/4“ 67 157 90 80 496 77 197 9,5 11
SMG 1550 VBHG 2000 l/h 1,1 kW 100 49 140 13 G 3/4“ 67 181 90 137 90 531 92 214 11 135
SMG 1551 VGHGP 3000 l/h 1,5 kW 125 65 140 13 G 1“ 80 181 120 137 90 617 95 214 11 135
SMG 1552 VBHGM 4500 l/h 2,2 kW 140 65 160 14 G 1“ 80 202 120 150 100 657 103 235 13 16
SMG 1553 VBHGG 6000 l/h 3,0 kW 140 65 160 14 G 1“ 80 202 120 150 100 657 103 235 13 16
                                     
SMG 1561 VBP 45 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1562 VBM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1563 VBG 120 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1564 VBF 160 l/h 0,37 kW 90 36 112 7 G 3/8“ 38 139 67 71 376 69 180 7 11
SMG 1565 VBGP 300 l/h 0,37 kW 90 43 112 7 G 1/2“ 44 139 75 71 390 69 180 7 11
SMG 1566 VBGM 450 l/h 0,75 kW 100 43 125 8 G 1/2“ 44 157 75 80 423 77 197 9,5 11
SMG 1567 VBGG 600 l/h 0,75 kW 100 43 125 8 G 1/2“ 44 157 75 80 423 77 197 9,5 11
SMG 1568 VBHP 1000 l/h 1,5 kW 125 49 140 13 G 3/4“ 67 181 90 137 90 531 92 214 11 135
SMG 1569 VBHM 1500 l/h 2,2 kW 140 49 160 14 G 3/4“ 67 202 80 150 100 595 110 235 13 16
SMG 1570 VBHG 2000 l/h 3,0 kW 140 49 160 14 G 3/4“ 67 202 90 150 100 595 110 235 13 16
SMG 1571 VBHGP 3000 l/h 4,0 kW 140 65 190 15 G 1“ 80 227 120 150 112 679 118 269 13 16
SMG 1572 VBHGM 4500 l/h 5,5 kW 140 65 216 17 G 1“ 80 267 120 183 132 740 140 308 13 21
SMG 1573 VBHGG 6000 l/h 7,5 kW 140 65 216 17 G 1“ 80 267 120 183 132 740 140 308 13 21
                                     
SMG 1922 VBM 80 l/h 0,18 kW 80 36 100 7 G 3/8“ 38 124 67 63 348 63 163 7 11
SMG 1923 VBG 120 l/h 0,37 kW 90 36 112 7 G 3/8“ 38 139 67 71 376 69 180 7 11
SMG 1924 VBF 160 l/h 0,37 kW 90 36 112 7 G 3/8“ 38 139 67 71 376 69 180 7 11
SMG 1925 VBGP 300 l/h 0,75 kW 100 43 125 8 G 1/2“ 44 157 75 80 423 77 197 9,5 11
SMG 1926 VBGM 450 l/h 1,1 kW 100 43 140 13 G 1/2“ 44 181 75 90 440 92 214 11 135
SMG 1927 VBGG 600 l/h 1,5 kW 125 43 140 13 G 1/2“ 44 181 75 90 440 92 214 11 135
SMG 1928 VBHP 1000 l/h 2,2 kW 140 49 160 14 G 3/4“ 67 202 90 150 100 595 110 235 13 16
SMG 1929 VBHM 1500 l/h 3,0 kW 140 49 160 14 G 3/4“ 67 202 90 150 100 595 110 235 13 16
SMG 1930 VBHG 2000 l/h 4,0 kW 140 49 190 15 G 3/4“ 67 227 90 163 112 617 118 269 13 16
SMG 1931 VBHGP 3000 l/h 5,5 kW 140 65 216 17 G 1“ 80 267 120 189 132 740 140 308 13 21
SMG 1932 VBHGM 4500 l/h 7,5 kW 178 65 216 17 G 1“ 80 267 120 189 132 740 140 308 13 21