Industrial Pumps and Special Pumps Index

hp TECHNIK Industrial Pumps

Just another WordPress site

B-Series without overflow valve

1.1

Industrial Pumps

Technical selection chart: scaled drawings

Direction of rotation viewed from shaft

I = indirect – counterclockwise

D = direct – clockwise

The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation as per the size chart/sheet when ordering!

hp-Internal gear pumps up to 40 bar

(direction I = indirect – counterclockwise)

Pump
series
B

Size:

Viscosity: 6 mm2 sec -1 bei 20° C Gear 
rotor
size
Ø
Shaft
Ø
Threaded
connection
for (S/A)
Manometer
connection
max. allowed
pump
RPM
(min -1)
at I/D
Net
weight
(kg)
at I/D
n = 1400 min -1
Discharge l/h
n = 2800 min -1
Discharge l/h
at
9 bar
at
30 bar
at
40 bar
Article-no.
I
at
9 bar
at
30 bar
at
40 bar
Article-no.
I
BP 45 30 20 011/0002 90 60 50 013/0002 25 12 3/8“ 2800 1.8
BM 80 60 50 011/0003 160 130 120 013/0003 25 12 3/8“ 2800 1.8
BG 120 100 80 011/0004 240 200 190 013/0004 25 12 3/8“ 2800 1.8
BF 160 140 120 011/0005 320 270 260 013/0005 25 12 3/8“ 2800 1.8
                             
BG PP 150 100 80 011/0052 300 240 210 013/0052 38 12 1/2“ 2800 2.6
BG PZ 200 160 140 011/0053 400 310 280 013/0053 38 12 1/2“ 2800 2.6
BG P 300 240 200 011/0019 600 520 480 013/0019 38 12 1/2“ 2800 2.6
BG MZ 850 750 700 013/0068 38 12 1/2“ 2800 2.6
BG M 450 390 360 011/0020 900 850 730 013/0020 38 12 1/2“ 2800 2.6
BG GZ 1100 1000 870 013/0054 38 12 1/2“ 2800 2.6
BG G 600 540 480 011/0021 1200 1080 960 013/0031 38 12 1/2“ 1680 2.6
                             
BH P 1000 700 600 011/0031 56 18 3/4“ 1/4“ 1680 6.4
BH M 1500 1200 1000 011/0032 56 18 3/4“ 1/4“ 1680 6.4
BH G 2000 1700 1400 011/0033 56 18 3/4“ 1/4“ 1680 6.4
                             
BHG P 3000 2200 2000 011/0043 75 22 1 1/2“ 1400 14.9
BHG PZ 3700 3000 2700 011/0080 75 22 1 1/2“ 1400 14.9
BHG M 4500 3600 3200 011/0044 75 22 1 1/2“ 1400 14.9
BHG G 6000 4800 011/0045 75 22 1 1/2“ 1400 14.9

hp-Internal gear pumps up to 40 bar

(direction D = direct – clockwise)

Pump
series
B

Size:

Viscosity: 6 mm2 sec -1 bei 20° C Gear 
rotor
size
Ø
Shaft
Ø
Threaded
connection
for (S/A)
Manometer
connection
Heating
capacity
H1 in watt
at 220V, 50HZ
at I/D
Initial
Pump
breakaway
forque
at I/D
n = 1400 min -1
Discharge l/h
n = 2800 min -1
Discharge l/h
at
9 bar
at
30 bar
at
40 bar
Article-no.
D
at
9 bar
at
30 bar
at
40 bar
Article-no.
D
BP 45 30 20 012/0002   90 60 50 014/0002 25 12 3/8“ 100 1,2
BM 80 60 50 012/0003 160 130 120 014/0003 25 12 3/8“ 100 1,2
BG 120 100 80 012/0004 240 200 190 014/0004 25 12 3/8“ 100 1,2
BF 160 140 120 012/0005 320 270 260 014/0005 25 12 3/8“ 100 1,2
                             
BG PP 150 100 80 012/0052 300 240 210 014/0052 38 12 1/2“ 100 1,6
BG PZ 200 160 140 012/0053 400 310 280 014/0053 38 12 1/2“ 100 1,6
BG P 300 240 200 012/0019 600 520 480 014/0019 38 12 1/2“ 100 1,6
BG MZ 850 750 700 014/0068 38 12 1/2“ 100 1,6
BG M 450 390 360 012/0020 900 850 730 014/0020 38 12 1/2“ 100 1,6
BG GZ 1100 1000 870 014/0054 38 12 1/2“ 100 1,6
BG G 600 540 480 012/0021 1200 1080 960 014/0031 38 12 1/2“ 100 1,6
                             
BH P 1000 700 600 012/0031 56 18 3/4“ 1/4“ 160 3,2
BH M 1500 1200 1000 012/0032 56 18 3/4“ 1/4“ 160 3,2
BH G 2000 1700 1400 012/0033 56 18 3/4“ 1/4“ 160 3,2
                             
BHG P 3000 2200 2000 012/0043 75 22 1 1/2“ 280 4,6
BHG PZ 3700 3000 2700 012/0080 75 22 1 1/2“ 280 4,6
BHG M 4500 3600 3200 012/0044 75 22 1 1/2“ 280 4,6
BHG G 6000 4800 012/0045 75 22 1 1/2“ 280 4,6

*To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site! The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.

Print Friendly