General details:
| Operating viscosity: |
The motor output data applies for fluids with a viscositys up
to 80 cSt. From 80 cSt to 150 cSt, the motor must be one
power stage size stronger.
Available at a surcharge upon request. |
| |
|
| max. suction head: |
measured in terms of the manometer (Pos. 5) = - 0,6 bar |
| |
|
| max. inlet pressure |
= pressure load of the axial face seal: - 0,6 - + 5 bar |
| |
|
| max. nozzle loss |
= 70 % of discharge at pmax |
|
 |
 |
 |
Twin pumping unit BIK 5000 according to Scheme I and II without bypass
|
Connections
Suction/Pressure
Screwed/Flanged |
Aggregate
Type |
Discharge at
1400 min-1
at 0 - 9 bar
in l/h |
Pump Type
Series VB |
Motor
Output
in kW |
Series key |
Dimension
Length/Height/Breadth |
Execution with double
filter
according
to Scheme II |
| Series key |
max. pressure
in bar |
| Pipe D 12/without flange |
BIK 5000-1 |
45 |
VBP |
0,18 |
520046 |
600 x 500 x 550 |
– |
designed for max.
working pressure
of 9 bar
per DIN/EN
12514/1 max.
working pressure
of 6 bar |
| Pipe D 12/without flange |
BIK 5000-2 |
80 |
VBM |
0,18 |
520047 |
600 x 500 x 550 |
– |
| Pipe D 12/without flange |
BIK 5000-3 |
120 |
VBG |
0,18 |
520048 |
600 x 500 x 550 |
– |
| Pipe D 12/without flange |
BIK 5000-4 |
160 |
VBF |
0,18 |
520049 |
600 x 500 x 550 |
– |
| |
|
|
|
|
|
|
|
| DN 15/DN 15 |
BIK 5000-5 |
300 |
VBGP |
0,18 |
520050 |
600 x 500 x 550 |
520090 |
| DN 15/DN 15 |
BIK 5000-6 |
450 |
VBGM |
0,37 |
520056 |
600 x 500 x 550 |
520091 |
| DN 15/DN 15 |
BIK 5000-7 |
600 |
VBGG |
0,37 |
520057 |
600 x 500 x 550 |
520092 |
| |
|
|
|
|
|
|
|
| DN 25/DN 25 |
BIK 5000-8 |
1000 |
VBHP |
0,55 |
520058 |
800 x 700 x 700 |
520093 |
| DN 25/DN 25 |
BIK 5000-9 |
1500 |
VBHM |
0,75 |
520059 |
800 x 700 x 700 |
520094 |
| DN 25/DN 25 |
BIK 5000-10 |
2000 |
VBHG |
1,1 |
520060 |
800 x 700 x 700 |
520095 |
| |
|
|
|
|
|
|
|
| DN 32/DN 32 |
BIK 5000-11 |
3000 |
VBHGP |
1,5 |
520061 |
800 x 700 x 800 |
520096 |
| DN 32/DN 32 |
BIK 5000-12 |
4500 |
VBHGM |
2,2 |
520062 |
800 x 700 x 800 |
520097 |
| DN 32/DN 32 |
BIK 5000-13 |
6000 |
VBHGG |
3,0 |
520063 |
800 x 700 x 800 |
520098 |
|
 |
 |
To insure proper unit function, all pipe attachments must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site.
The size of the pump and/or device attachments is not indicative of the pipe attachment size which must be used.
Note for the screwed version: When using a Cu pipe it is imperative that the appropriate EO supporting sleeve be used for EO threaded pipe attachments for DIN 1630 and 2391 steel pipes.
|
|
|