General details:
| Operating viscosity: |
The motor output data applies for fluids with a viscositys up
to 80 cSt. From 80 cSt to 150 cSt, the motor must be one
power stage size stronger.
Available at a surcharge upon request. |
| |
|
| max. suction head: |
measured in terms of the manometer (Pos. 5) = - 0,6 bar |
| |
|
| max. inlet pressure |
= pressure load of the axial face seal: - 0,6 - + 5 bar |
| |
|
| max. nozzle loss |
= 70 % of discharge at pmax |
|
 |
 |
 |
Single pumping unit MOG 50 according to Scheme I without bypass
|
Connections
Suction/pressure
Screwed/Flanged |
Aggregat
Type |
Discharge at
1400 min-1 |
Pump Type
Series VB |
Motor Output
in kW |
Execution according
to Scheme I |
max pressure
in bar |
Refer to
key of mode
of operation |
Discharge
rating |
at 0 -9 bar
in l/h |
at
pmax
in l/h
|
Screwed
Series key |
Flanged
Series key |
| Pipe D 12/without flange |
MOG 50 |
1 |
45 |
– |
VBP |
0,18 |
510101 |
– |
designed for
max. working
pressure
of 9 bar
per DIN/EN
12514/1
max.
working
pressure
of 6 bar |
| Pipe D 12/without flange |
MOG 50 |
2 |
80 |
– |
VBM |
0,18 |
510102 |
– |
| Pipe D 12/without flange |
MOG 50 |
3 |
120 |
– |
VBG |
0,18 |
510103 |
– |
| Pipe D 12/without flange |
MOG 50 |
4 |
160 |
– |
VBF |
0,18 |
510104 |
– |
| |
|
|
|
|
|
|
|
| Pipe 18/DN 15 |
MOG 50 |
5 |
300 |
– |
VBGP |
0,18 |
510105 |
| Pipe 18/DN 15 |
MOG 50 |
6 |
450 |
– |
VBGM |
0,37 |
510106 |
| Pipe 18/DN 15 |
MOG 50 |
7 |
600 |
– |
VBGG |
0,37 |
510107 |
| |
|
|
|
|
|
|
|
| DN 25 |
MOG 50 |
8 |
1000 |
– |
VBHP |
0,55 |
510108 |
| DN 25 |
MOG 50 |
9 |
1500 |
– |
VBHM |
0,75 |
510109 |
| DN 25 |
MOG 50 |
10 |
2000 |
– |
VBHG |
1,1 |
510110 |
| |
|
|
|
|
|
|
|
|
| DN 32 |
MOG 50 |
11 |
3000 |
– |
VBHGP |
1,5 |
– |
510211 |
| DN 32 |
MOG 50 |
12 |
4500 |
– |
VBHGM |
2,2 |
– |
510212 |
| DN 40 |
MOG 50 |
13 |
6000 |
– |
VBHGG |
3,0 |
– |
510213 |
|
 |
Single pumping unit MOG 51 according to Scheme II without bypass
|
Connections
Suction/pressure
Screwed/Flanged |
Aggregat
Type |
Discharge at
1400 min-1 |
Pump Type
Series VB |
Motor Output
in kW |
Execution according
to Scheme I |
max pressure
in bar |
Refer to
key of mode
of operation |
Discharge
rating |
at 0 -9 bar
in l/h |
at
pmax
in l/h |
Screwed
Series key |
Flanged
Series key |
| Pipe D 18/without flange |
MOG 51 |
1 |
45 |
– |
VBP |
0,18 |
510114 |
– |
designed for max.
working pressure
of 9 bar |
| Pipe D 18/without flange |
MOG 51 |
2 |
80 |
– |
VBM |
0,18 |
510115 |
– |
| Pipe D 18/without flange |
MOG 51 |
3 |
120 |
– |
VBG |
0,18 |
510116 |
– |
| Pipe D 18/without flange |
MOG 51 |
4 |
160 |
– |
VBF |
0,18 |
510117 |
– |
| |
|
|
|
|
|
|
|
|
| Pipe 18/DN 15 |
MOG 51 |
5 |
300 |
– |
VBGP |
0,18 |
510118 |
510218 |
| Pipe 18/DN 15 |
MOG 51 |
6 |
450 |
– |
VBGM |
0,37 |
510119 |
510219 |
| Pipe 18/DN 15 |
MOG 51 |
7 |
600 |
– |
VBGG |
0,37 |
510120 |
510220 |
| |
|
|
|
|
|
|
|
|
| DN 25 |
MOG 51 |
8 |
1000 |
– |
VBHP |
0,55 |
– |
510221 |
| DN 25 |
MOG 51 |
9 |
1500 |
– |
VBHM |
0,75 |
– |
510222 |
| DN 25 |
MOG 51 |
10 |
2000 |
– |
VBHG |
1,1 |
– |
510223 |
| |
|
|
|
|
|
|
|
|
| DN 32 |
MOG 51 |
11 |
3000 |
– |
VBHGP |
1,5 |
– |
510224 |
| DN 32 |
MOG 51 |
12 |
4500 |
– |
VBHGM |
2,2 |
– |
510225 |
| DN 40 |
MOG 51 |
13 |
6000 |
– |
VBHGG |
3,0 |
– |
510226 |
|
1) The suction connection on the side is A = G 1 ½" on SMG 1611 - SMG 1631, SMG 1631 - 1630, SMG 1951 - 1952.
To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site!
The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.
|
|
|