HP Technik Industrial Pumps  
 
Home | News | Products | Info | Order | Contact |
Search |
 
  hp Motor Pump Groups; SMG Series

Series NV with Integrated Overflow Valve and Bypass

Single systems with 1400 min-1 and hp industrial pumps.

System up to 9 bar: Pressure stage 2 = 2 to 9 bar.
Limited as per DIN 4736 to 6 bar.
System up to 30 or 40 bar: Pressure stage 4 =15 to 40 bar..


Suitable for use with hydraulic oils, lubricating oils, all fuel oils, coal and lignite tar oils, kerosene and many other self-lubricating fluids. The motor output data applies for fluids with a viscosity of up to 80 cSt. From 80 to 150 cSt, the motor must be one power stage size stronger. Available at a surcharge upon request.

TV RheinlandThe pump connections are indicated as follows:
A = suction connection
S = delivery connection
R = bypass connection

The standard models of the pumps are designed with a counterclockwise direction of rotation (viewed from the pump shaft). The position of the pump connections is independent of the direction of rotation.
(See illustration.)


Direction of rotation l = counterclockwise, standard model
For clockwise rotation, D, the oil connections A = suction and S = delivery are interchanged. The middle connection remains unchanged.

 heating Graph
Series
Size
Pump
Type
Discharge at
1400 min-1
Motor
Output
Connections1) * H1 Heater
Watt
Gear
Rotor/Shaft
Article No.
at 0 - 9 bar at 25 bar
SMG 1701 NVBRP 45 l/h 0,18 kW G 3/8" 100 25/12 370001 pmax 9 bar
SMG 1702 NVBRM 80 l/h 0,18 kW G 3/8" 100 25/12 370002
SMG 1703 NVBRG 120 l/h 0,18 kW G 3/8" 100 25/12 370003
SMG 1704 NVBRF 160 l/h 0,18 kW G 3/8" 100 25/12 370004
                 
SMG 1705 NVBGRP 300 l/h 0,18 kW G ½" 100 38/12 370005
SMG 1706 NVBGRM 450 l/h 0,37 kW G ½" 100 38/12 370006
SMG 1707 NVBGRG 600 l/h 0,37 kW G ½" 100 38/12 370007
                 
SMG 1708 NVBHRP 1000 l/h 0,75 kW G ¾" 160 56/18 370008
SMG 1709 NVBHRM 1500 l/h 0,75 kW G ¾" 160 56/18 370009
SMG 1710 NVBHRG 2000 l/h 1,1 kW G ¾" 160 56/18 370010
                 
SMG 1721 NVBRP 45 l/h 30 l/h 0,18 kW G 3/8" 100 25/12 370011
SMG 1722 NVBRM 80 l/h 60 l/h 0,18 kW G 3/8" 100 25/12 370012 pmax 25 bar
SMG 1723 NVBRG 120 l/h 100 l/h 0,18 kW G 3/8" 100 25/12 370013
SMG 1724 NVBRF 160 l/h 140 l/h 0,37 kW G 3/8" 100 25/12 370014
SMG 1725 NVBGRP 300 l/h 240 l/h 0,37 kW G ½" 100 38/12 370015
SMG 1726 NVBGRM 450 l/h 390 l/h 0,75 kW G ½" 100 38/12 370016
SMG 1727 NVBGRG 600 l/h 520 l/h 0,75 kW G ½" 100 38/12 370017
                 
SMG 1728 NVBHRP 1000 l/h 700 l/h 1,5 kW G ¾" 160 56/18 370018
SMG 1729 NVBHRM 1500 l/h 1200 l/h 2,2 kW G ¾" 160 56/18 370019
SMG 1730 NVBHRG 2000 l/h 1700 l/h 3,0 kW G ¾" 160 56/18 370020
Series
Size
Pump
Type
Discharge at
1400 min-1
Motor
Output
Connections1) * H1 Heater
Watt
Gear
Rotor/Shaft
Article No.
at 0 bar at 40 bar
SMG 1962 NVBRM 80 l/h 50 l/h 0,18 kW G 3/8" 100 25/12 390067 pmax 40 bar
SMG 1963 NVBRG 120 l/h 80 l/h 0,37 kW G 3/8" 100 25/12 390068
SMG 1964 NVBRF 160 l/h 120 l/h 0,37 kW G 3/8" 100 25/12 390069
                 
SMG 1965 NVBGRP 300 l/h 200 l/h 0,75 kW G ½" 100 38/12 390070
SMG 1966 NVBGRM 450 l/h 360 l/h 1,1 kW G ½" 100 38/12 390071
SMG 1967 NVBGRG 600 l/h 480 l/h 1,5 kW G ½" 100 38/12 390072
SMG 1968 NVBHRP 1000 l/h 600 l/h 2,2 kW G ¾" 160 56/18 390073
SMG 1969 NVBHRM 1500 l/h 1000 l/h 3,0 kW G ¾" 160 56/18 390074
SMG 1970 NVBHRG 2000 l/h 1400 l/h 4,0 kW G ¾" 160 56/18 390075


1) Cyl. Withworth Pipe Threading: G…A DIN ISO 228
* To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site!
The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.

Scaled Drawings for Series B
Series B
Series
Size
Pump
Type
Dis-
charge
Motor
Output
Dimensions
a a1 b c e1 f3 g g1 g2 h k k1 p s Pg
SMG 1701 NVBRP 45 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1702 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1703 NVBRG 120 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1704 NVBRF 160 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1705 NVBGRP 300 l/h 0,18 kW 80 43 100 7 G ½" 35 124 72 63 362 63 163 7 11
SMG 1706 NVBGRM 450 l/h 0,37 kW 90 43 112 7 G ½" 35 139 72 71 390 69 180 7 11
SMG 1707 NVBGRG 600 l/h 0,37 kW 90 43 112 7 G ½" 35 139 72 71 390 69 180 7 11
SMG 1708 NVBHRP 1000 l/h 0,75 kW 100 49 125 8 G ¾" 50 157 105 80 496 77 197 9,5 11
SMG 1709 NVBHRM 1500 l/h 0,75 kW 100 49 125 8 G ¾" 50 157 105 80 496 77 197 9,5 11
SMG 1710 NVBHRG 2000 l/h 1,1 kW 100 49 140 13 G ¾" 50 181 105 137 90 531 92 214 11 13,5
                                     
SMG 1721 NVBRP 45 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1722 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1723 NVBRG 120 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1724 NVBRF 160 l/h 0,37 kW 90 36 112 7 G 3/8" 32,5 139 67 71 376 69 180 7 11
SMG 1725 NVBGRP 300 l/h 0,37 kW 90 43 112 7 G ½" 35 139 72 71 390 69 180 7 11
SMG 1726 NVBGRM 450 l/h 0,75 kW 100 43 125 8 G ½" 35 157 72 80 423 77 197 9,5 11
SMG 1727 NVBGRG 600 l/h 0,75 kW 100 43 125 8 G ½" 35 157 72 80 423 77 197 9,5 11
SMG 1728 NVBHRP 1000 l/h 1,5 kW 125 49 140 13 G ¾" 50 181 105 137 90 531 92 214 11 13,5
SMG 1729 NVBHRM 1500 l/h 2,2 kW 140 49 160 14 G ¾" 50 202 105 150 100 595 110 235 13 16
SMG 1730 NVBHRG 2000 l/h 3,0 kW 140 49 160 14 G ¾" 50 202 105 150 100 595 110 235 13 16
                                     
SMG 1962 NVBRM 80 l/h 0,18 kW 80 36 100 7 G 3/8" 32,5 124 67 63 348 63 163 7 11
SMG 1963 NVBRG 120 l/h 0,37kW 90 36 112 7 G 3/8" 32,5 139 67 71 376 69 180 7 11
SMG 1964 NVBRF 160 l/h 0,37 kW 90 36 112 7 G 3/8" 32,5 139 67 71 376 69 180 7 11
SMG 1965 NVGRP 300 l/h 0,75 kW 100 43 125 8 G ½" 35 157 75 80 423 77 197 9,5 11
SMG 1966 NVBGRM 450 l/h 0,75 kW 100 43 125 8 G ½" 35 157 75 80 423 77 197 9,5 11
SMG 1967 NVBGRG 600 l/h 1,1 kW 100 43 140 13 G ½" 35 181 75 90 440 92 214 11 13,5
SMG 1968 NVBHRP 1000 l/h 2,2 kW 140 49 160 14 G ¾" 50 202 105 150 100 595 110 235 13 16
SMG 1969 NVBHRM 1500 l/h 3,0 kW 140 49 160 14 G ¾" 50 202 105 150 100 595 110 235 13 16
SMG 1970 NVBHRG 2000 l/h 4,0 kW 140 49 190 15 G ¾" 50 227 105 163 112 617 118 269 13 16


 
 
 
 
 
hp-TECHNIK · Gablonzer Str. 21 · 76185 Karlsruhe · Tel (49) 721/956 18-0 · Fax (49) 721/956 18-28
 
 
FREE hp-TECHNIK Catalog on CD-ROM! Click here >
 
  
 

Home | News | Products | Info | Order | Contact | Index

© 2008 hp-TECHNIK GmbH Industrial Pumps, Oil Transfer, Production and Manufacturing Systems

 