Horizontal single system with hp industrial pumps with axial face
seal able to handle pressures up to 5 bar and max. 150 °C.
Easy to operate. Very safe. Exceptionally quiet. High suction capacity and operating life.
When used as supply aggregate for fuel oil feed as per DIN 4736,
the max operating pressure may not exceed 6 bar2).
| When used: |
as discharge or supply unit;designed for pressures of up to 9 bar.
as pressure or spray unit; designed for pressures of up to 30 bar.
for higher pressures; designed for pressures of up to 40 bar. |
 |
The pump groups are equipped whith three-phase standard motors B3/B14 or B3/B5,
400 V, 50 Hz, 1400 min-1, protection standard IP 54, Isolation class F.
From 4 kW, the motors are threaded for 400/690 V, 50 Hz.
Y-Δ-cirquit with power supply must be indicated when ordering. |
 |
Other voltages and frequencies are available at a surcharge upon request. |
 |
Mounting position: Horizontal, with the connections facing upwards. |
|
Key for determination of the order numbers:
|
| Series
Size |
Direction
of rotation 1) viewed from pump shaft
|
Pressure
Range bar
|
Special
Production and Accessories
(add code letters consecutively) |
e.g.: SMG 1507
See price lists.. |
l =
counterclockwise,
standard model
D = clockwise,
on request |
0 = 0,5 -
1,5
1 = 1 - 4
2 = 2 - 9
3 = 6 - 25
4 = 15 - 40 |
H1 = Electric heating with heating cartridge, see tables for heating capacity.(See pump
accessories here.)
Wa = With oil pan and anti-vibration pads for mounting on the wall.
(See accessories here.)
LH = Oil pan can be equipped with a floating magnetic switch for "oil leak detection".
S2) = With electric pressure switch for pressure line
monitoring. (Pipe-burst check.)
DT = Pressure transmitter |
| |
|
|
Max. permissible vacuum pressure at pump connection A -0.6 bar
Warning, gas discharge starts at -0.4 bar |
|
 |
Ordering example: hp motor pump group series size SMG 1568 with hp industrial pump type VBHP-I with integrated overflow valve;
direction of rotation viewed from pump shaft: I = counterclockwise; flow rate: 700 l/h at 1400 min-1 and 25 bar; operating pressure: 25 bar;
pressure range: 15 to 25 bar; max. pressure: 25 bar; medium: fuel oil S; Viscosiy: 6 cSt. at 140 ° C; motor output: 1,5 kW, voltage 230/400V, 50Hz,
isolation class B; protection standard: IP 54; accessories: axial face seal Viton V, electric heating H1.
Order No.: SMG 1568 - I - 3 - H1 |
 |
| For assembly, start-up and maintenance, please adhere to the instruction manual that comes with each device! |
 |
1) A pump's direction of rotation can only be changed in the factory!
2) Note: It is absolutely imperative that the user install an electric pressure control switch (acting as a "lower limit controller"), as pipe pressure safety device, on the equipment to which the pump is to be
connected. This prerequisite can be met by ordering accessory "S".
|
|
|