HP Technik Industrial Pumps  
 
Home | News | Products | Info | Order | Contact |
Search |
 
  Series VBR; With Intergrated Overflow Valve and Bypass

Series VBRTechnical Selection Chart: Scaled Drawings

Direction of rotation viewed from Shaft
I = indirect – counterclockwise
D= direct – clockwise

The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation as per the size chart/sheet when ordering!
hp internal gear pumps up to 40 bar (Direction I = indirect - counterclockwise)
Pump
Series
VBR


Size:
Viscosity: 6 mm2 sec-1 at 20° C


Gear
Rotor
Size

Ø





Shaft

Ø
Threaded
Connection
for
(S/A/R)
Mano-
meter
Con-
nection
max.
allowed
Pump
RPM
(min-1)

at I/D
Net
weight
(kg)



at I/D
n = 1400 min-1
Discharge l/h
n = 2800 min-1
Discharge l/h
at 9 bar at 30 bar at 40 bar Article No. I at 9 bar at 30 bar at 40 bar Article No. I
VBR P 45 30 20 011/0011 90 60 50 013/0011 25 12 3/8" 2800 2,5
VBR M 80 60 50 011/0012 160 130 120 013/0012 25 12 3/8" 2800 2,5
VBR G 120 100 80 011/0013 240 200 190 013/0013 25 12 3/8" 2800 2,5
VBR F 160 140 120 011/0014 320 270 260 013/0014 25 12 3/8" 2800 2,5
VBGR PP 150 100 80 011/0065 300 240 210 013/0040 38 12 ½" 2800 3,3
VBGR PZ 200 160 140 011/0062 400 310 280 013/0041 38 12 ½" 2800 3,3
VBGR P 300 240 200 011/0025 600 520 480 013/0023 38 12 ½" 2800 3,3
VBGR MZ 850 750 700 013/0072 38 12 ½" 2800 3,3
VBGR M 450 390 360 011/0026 900 850 730 013/0024 38 12 ½" 2800 3,3
VBGR GZ 1100 1000 870 013/0042 38 12 ½" 2800 3,3
VBGR G 600 540 480 011/0027 38 12 ½" 1680 3,3
VBHR P 1000 700 600 011/0037 56 18 ¾" 1680 7,3
VBHR M 1500 1200 1000 011/0038 56 18 ¾" 1680 7,3
VBHR G 2000 1700 1400 011/0039 56 18 ¾" 1680 7,3
VBHGR P 3000 2200 2000 011/0049 75 22 1 " ¼" 1400 18,6
VBHGR PZ 3700 3000 2700 011/0090 75 22 1" ¼" 1400 18,6
VBHGR M 4500 3600 3200 011/0050 75 22 1" ¼" 1400 18,6
VBHGR G 6000 4800 011/0051 75 22 1" ¼" 1400 18,6
hp internal gear pumps up to 40 bar (Direction D = direct - clockwise)
Pump Series VBR
Size:
Viscosity: 6 mm2 sec-1 at 20° C



Gear
Rotor
Size

Ø






Shaft

Ø
Threaded
Connection
for (S/A/R)
Mano-meter
Con-nection
Heating
Capacity
H1 in Watt

at 220V, 50Hz
at I/D
Initial
Pump
Break-
away
Torque



at I/D
n = 1400 min-1
Discharge l/h
n = 2800 min-1
Discharge l/h
at
9 bar
at
30 bar
at
40 bar
Article No. D at
9 bar
at
30 bar
at
40 bar
Article No. D
VBR P 45 30 20 012/0011 90 60 50 014/0011 25 12 3/8" 100 1,2
VBR M 80 60 50 012/0012 160 130 120 014/0012 25 12 3/8" 100 1,2
VBR G 120 100 80 012/0013 240 200 190 014/0013 25 12 3/8" 100 1,2
VBR F 160 140 120 012/0014 320 270 260 014/0014 25 12 3/8" 100 1,2
VBGR PP 150 100 80 012/0065 300 240 210 014/0040 38 12 ½" 100 1,6
VBGR PZ 200 160 140 012/0062 400 310 280 014/0041 38 12 ½" 100 1,6
VBGR P 300 240 200 012/0025 600 520 480 014/0023 38 12 ½" 100 1,6
VBGR MZ 850 750 700 014/0072 38 12 ½" 100 1,6
VBGR M 450 390 360 012/0026 900 800 730 014/0024 38 12 ½" 100 1,6
VBGR GZ 1100 930 870 014/0042 38 12 ½" 100 1,6
VBGR G 600 540 480 012/0027 38 12 ½" 100 1,6
VBHR P 1000 700 600 012/0037 56 18 ¾" 160 3,2
VBHR M 1500 1200 1000 012/0038 56 18 ¾" 160 3,2
VBHR G 2000 1700 1400 012/0039 56 18 ¾" 160 3,2
VBHGR P 3000 2200 2000 012/0049 75 22 1" ¼" 280 4,6
VBHGR PZ 3700 3000 2700 012/0090 75 22 1" ¼" 280 4,6
VBHGR M 4500 3600 3200 012/0050 75 22 1" ¼" 280 4,6
VBHGR G 6000 4800 012/0051 75 22 1" ¼" 280 4,6


* To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site! The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used.
Scaled Drawings for Series VBR
Series VBR
Model Discharge l/h a1 a2 a3 b1 c1 c2 c3 c4 c5 c6 c7 c8
1400 min-1 2800 min-1
25 45 - 160 90 - 320 35,5 20 33 51 41,5 14 16 40 20 55,5 76 131,5
38 150 - 600 300 - 1100 39,5 30 38 70 55,5 14 16 40 20 69,5 76 145,5
56 1000 - 2000 48,5 38 45 96 71,5 15 18 79 27 86,5 124 210,5
75 3000 - 6000 62,5 85 70 115 129,5 18 25 65 37 147,5 127 274,5
Model Discharge l/h d1 sw e d2 d3 e1 *e2 f1 f2 f3 f4 f5
1400 min-1 2800 min-1
25 45 - 160 90 - 320 12 27 31,2 54 80 G 3/8" G 3/8" 139 32 90 17 26
38 150 - 600 300 - 1100 12 27 31,2 54 80 G ½" G 3/8" 139 32 90 17 23
56 1000 - 2000 18 46 53 60 100 G ¾" G 3/8" 162 26,5 118 17,5 25,5
75 3000 - 6000 22 55 63,5 80 120 G 1" 1) G 3/8" 211 36 150 25 35
Model Discharge l/h f6 f7 f8 f9 g1 g2 g3 g4 g5 h1 h2 h3
1400 min-1 2800 min-1
25 45 - 160 90 - 320 38 92 140 18 30 33 63 27 90 11 13 13
38 150 - 600 300 - 1100 44 92 140 18 32 35 67 27 94 11 13 13
56 1000 - 2000 67 120 171 26,5 38 42 80 35 115 13 13 25
75 3000 - 6000 80 150 218 32 18 62 80 40 120 14,5 15


VBHGR model with G ¼" manometer connection at the face.
1) Given a motive force of 75 = 3000 to 6000 l/h, the suction connection at the side is G1 ½".


 
 
 
 
 
hp-TECHNIK · Gablonzer Str. 21 · 76185 Karlsruhe · Tel (49) 721/956 18-0 · Fax (49) 721/956 18-28
 
 
FREE hp-TECHNIK Catalog on CD-ROM! Click here >
 
  
 

Home | News | Products | Info | Order | Contact | Index

© 2008 hp-TECHNIK GmbH Industrial Pumps, Oil Transfer, Production and Manufacturing Systems

 
  Fancy Media Internet Solutions