Technical Selection Chart: Scaled Drawings
Direction of rotation viewed from Shaft
I = indirect – counterclockwise
D= direct – clockwise
The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation as per the size chart/sheet when ordering!
|
|
hp internal gear pumps up to 40 bar (Direction I = indirect - counterclockwise) |
Pump
Series
VBR
Size: |
Viscosity: 6 mm2 sec-1 at 20° C |
Gear
Rotor
Size
Ø |
Shaft
Ø |
Threaded
Connection
for
(S/A/R) |
Mano-
meter
Con-
nection |
max.
allowed
Pump
RPM
(min-1)
at I/D |
Net
weight
(kg)
at I/D |
n = 1400 min-1
Discharge l/h |
n = 2800 min-1
Discharge l/h |
| at 9 bar |
at 30 bar |
at 40 bar |
Article No.
I |
at 9 bar |
at 30 bar |
at 40 bar |
Article No.
I |
| VBR P |
45 |
30 |
20 |
011/0011 |
90 |
60 |
50 |
013/0011 |
25 |
12 |
3/8" |
– |
2800 |
2,5 |
| VBR M |
80 |
60 |
50 |
011/0012 |
160 |
130 |
120 |
013/0012 |
25 |
12 |
3/8" |
– |
2800 |
2,5 |
| VBR G |
120 |
100 |
80 |
011/0013 |
240 |
200 |
190 |
013/0013 |
25 |
12 |
3/8" |
– |
2800 |
2,5 |
| VBR F |
160 |
140 |
120 |
011/0014 |
320 |
270 |
260 |
013/0014 |
25 |
12 |
3/8" |
– |
2800 |
2,5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBGR PP |
150 |
100 |
80 |
011/0065 |
300 |
240 |
210 |
013/0040 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR PZ |
200 |
160 |
140 |
011/0062 |
400 |
310 |
280 |
013/0041 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR P |
300 |
240 |
200 |
011/0025 |
600 |
520 |
480 |
013/0023 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR MZ |
– |
– |
– |
– |
850 |
750 |
700 |
013/0072 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR M |
450 |
390 |
360 |
011/0026 |
900 |
850 |
730 |
013/0024 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR GZ |
– |
– |
– |
– |
1100 |
1000 |
870 |
013/0042 |
38 |
12 |
½" |
– |
2800 |
3,3 |
| VBGR G |
600 |
540 |
480 |
011/0027 |
– |
– |
– |
– |
38 |
12 |
½" |
– |
1680 |
3,3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBHR P |
1000 |
700 |
600 |
011/0037 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
1680 |
7,3 |
| VBHR M |
1500 |
1200 |
1000 |
011/0038 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
1680 |
7,3 |
| VBHR G |
2000 |
1700 |
1400 |
011/0039 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
1680 |
7,3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBHGR P |
3000 |
2200 |
2000 |
011/0049 |
– |
– |
– |
– |
75 |
22 |
1 " |
¼" |
1400 |
18,6 |
| VBHGR PZ |
3700 |
3000 |
2700 |
011/0090 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
1400 |
18,6 |
| VBHGR M |
4500 |
3600 |
3200 |
011/0050 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
1400 |
18,6 |
| VBHGR G |
6000 |
4800 |
– |
011/0051 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
1400 |
18,6 |
|
 |
|
hp internal gear pumps up to 40 bar (Direction D = direct - clockwise) |
Pump Series VBR
Size: |
Viscosity: 6 mm2 sec-1 at 20° C |
Gear
Rotor
Size
Ø |
Shaft
Ø |
Threaded
Connection
for (S/A/R) |
Mano-meter
Con-nection |
Heating
Capacity
H1 in Watt
at 220V, 50Hz
at I/D |
Initial
Pump
Break-
away
Torque
at I/D |
n = 1400 min-1
Discharge l/h |
n = 2800 min-1
Discharge l/h |
at
9 bar |
at
30 bar |
at
40 bar |
Article No. D |
at
9 bar |
at
30 bar |
at
40 bar |
Article No. D |
| VBR P |
45 |
30 |
20 |
012/0011 |
90 |
60 |
50 |
014/0011 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| VBR M |
80 |
60 |
50 |
012/0012 |
160 |
130 |
120 |
014/0012 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| VBR G |
120 |
100 |
80 |
012/0013 |
240 |
200 |
190 |
014/0013 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| VBR F |
160 |
140 |
120 |
012/0014 |
320 |
270 |
260 |
014/0014 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBGR PP |
150 |
100 |
80 |
012/0065 |
300 |
240 |
210 |
014/0040 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR PZ |
200 |
160 |
140 |
012/0062 |
400 |
310 |
280 |
014/0041 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR P |
300 |
240 |
200 |
012/0025 |
600 |
520 |
480 |
014/0023 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR MZ |
– |
– |
– |
– |
850 |
750 |
700 |
014/0072 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR M |
450 |
390 |
360 |
012/0026 |
900 |
800 |
730 |
014/0024 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR GZ |
– |
– |
– |
– |
1100 |
930 |
870 |
014/0042 |
38 |
12 |
½" |
– |
100 |
1,6 |
| VBGR G |
600 |
540 |
480 |
012/0027 |
– |
– |
– |
– |
38 |
12 |
½" |
– |
100 |
1,6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBHR P |
1000 |
700 |
600 |
012/0037 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
160 |
3,2 |
| VBHR M |
1500 |
1200 |
1000 |
012/0038 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
160 |
3,2 |
| VBHR G |
2000 |
1700 |
1400 |
012/0039 |
– |
– |
– |
– |
56 |
18 |
¾" |
– |
160 |
3,2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VBHGR P |
3000 |
2200 |
2000 |
012/0049 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
280 |
4,6 |
| VBHGR PZ |
3700 |
3000 |
2700 |
012/0090 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
280 |
4,6 |
| VBHGR M |
4500 |
3600 |
3200 |
012/0050 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
280 |
4,6 |
| VBHGR G |
6000 |
4800 |
– |
012/0051 |
– |
– |
– |
– |
75 |
22 |
1" |
¼" |
280 |
4,6 |
|
To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site!
The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used. |
 |
 |
 |
 |
 |
| Model |
Discharge l/h |
a1 |
a2 |
a3 |
b1 |
c1 |
c2 |
c3 |
c4 |
c5 |
c6 |
c7 |
c8 |
| 1400 min-1 |
2800 min-1 |
| 25 |
45 - 160 |
90 - 320 |
35,5 |
20 |
33 |
51 |
41,5 |
14 |
16 |
40 |
20 |
55,5 |
76 |
131,5 |
| 38 |
150 - 600 |
300 - 1100 |
39,5 |
30 |
38 |
70 |
55,5 |
14 |
16 |
40 |
20 |
69,5 |
76 |
145,5 |
| 56 |
1000 - 2000 |
– |
48,5 |
38 |
45 |
96 |
71,5 |
15 |
18 |
79 |
27 |
86,5 |
124 |
210,5 |
| 75 |
3000 - 6000 |
– |
62,5 |
85 |
70 |
115 |
129,5 |
18 |
25 |
65 |
37 |
147,5 |
127 |
274,5 |
|
 |
| Model |
Discharge l/h |
d1 |
sw |
e |
d2 |
d3 |
e1 |
*e2 |
f1 |
f2 |
f3 |
f4 |
f5 |
| 1400 min-1 |
2800 min-1 |
| 25 |
45 - 160 |
90 - 320 |
12 |
27 |
31,2 |
54 |
80 |
G 3/8" |
G 3/8" |
139 |
32 |
90 |
17 |
26 |
| 38 |
150 - 600 |
300 - 1100 |
12 |
27 |
31,2 |
54 |
80 |
G ½" |
G 3/8" |
139 |
32 |
90 |
17 |
23 |
| 56 |
1000 - 2000 |
– |
18 |
46 |
53 |
60 |
100 |
G ¾" |
G 3/8" |
162 |
26,5 |
118 |
17,5 |
25,5 |
| 75 |
3000 - 6000 |
– |
22 |
55 |
63,5 |
80 |
120 |
G 1" 1) |
G 3/8" |
211 |
36 |
150 |
25 |
35 |
|
 |
| Model |
Discharge l/h |
f6 |
f7 |
f8 |
f9 |
g1 |
g2 |
g3 |
g4 |
g5 |
h1 |
h2 |
h3 |
| 1400 min-1 |
2800 min-1 |
| 25 |
45 - 160 |
90 - 320 |
38 |
92 |
140 |
18 |
30 |
33 |
63 |
27 |
90 |
11 |
13 |
13 |
| 38 |
150 - 600 |
300 - 1100 |
44 |
92 |
140 |
18 |
32 |
35 |
67 |
27 |
94 |
11 |
13 |
13 |
| 56 |
1000 - 2000 |
– |
67 |
120 |
171 |
26,5 |
38 |
42 |
80 |
35 |
115 |
13 |
13 |
25 |
| 75 |
3000 - 6000 |
– |
80 |
150 |
218 |
32 |
18 |
62 |
80 |
40 |
120 |
14,5 |
15 |
– |
|
VBHGR model with G ¼" manometer connection at the face.
1) Given a motive force of 75 = 3000 to 6000 l/h, the suction connection at the side is G1 ½".
|
|
|