Technical Selection Chart: Scaled Drawings
Direction of rotation viewed from Shaft
I = indirect – counterclockwise
D = direct – clockwise
The direction of rotation can only be changed in the factory. Therefore please assure that you state the desired direction of rotation as per the size chart/sheet when ordering!
|
|
hp internal gear pumps up to 40 bar (Direction I = indirect - counterclockwise) |
Pump
Series B
Size: |
Viscosity: 6 mm2 sec-1 at 20° C |
Gear Rotor
Size
Ø |
Shaft
Ø |
Threaded Connection for (S/A) |
Mano-
meter
Con-
nection |
max. allowed
Pump
RPM
(min-1)
at I/D |
Net
weight
(kg)
at I/D |
n = 1400 min-1
Discharge l/h |
n = 2800 min-1
Discharge l/h |
| at 9 bar |
at 30 bar |
at 40 bar |
Article No.
I |
at
9 bar |
at
30 bar |
at
40 bar |
Article No.
I |
| BP |
45 |
30 |
20 |
011/0002 |
90 |
60 |
50 |
013/0002 |
25 |
12 |
3/8" |
– |
2800 |
1,8 |
| BM |
80 |
60 |
50 |
011/0003 |
160 |
130 |
120 |
013/0003 |
25 |
12 |
3/8" |
– |
2800 |
1,8 |
| BG |
120 |
100 |
80 |
011/0004 |
240 |
200 |
190 |
013/0004 |
25 |
12 |
3/8" |
– |
2800 |
1,8 |
| BF |
160 |
140 |
120 |
011/0005 |
320 |
270 |
260 |
013/0005 |
25 |
12 |
3/8" |
– |
2800 |
1,8 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BG PP |
150 |
100 |
80 |
011/0052 |
300 |
240 |
210 |
013/0052 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG PZ |
200 |
160 |
140 |
011/0053 |
400 |
310 |
280 |
013/0053 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG P |
300 |
240 |
200 |
011/0019 |
600 |
520 |
480 |
013/0019 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG MZ |
– |
– |
– |
– |
850 |
750 |
700 |
013/0068 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG M |
450 |
390 |
360 |
011/0020 |
900 |
850 |
730 |
013/0020 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG GZ |
– |
– |
– |
– |
1100 |
1000 |
870 |
013/0054 |
38 |
12 |
½" |
– |
2800 |
2,6 |
| BG G |
600 |
540 |
480 |
011/0021 |
– |
– |
– |
– |
38 |
12 |
½" |
– |
1680 |
2,6 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BH P |
1000 |
700 |
600 |
011/0031 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
1680 |
6,4 |
| BH M |
1500 |
1200 |
1000 |
011/0032 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
1680 |
6,4 |
| BH G |
2000 |
1700 |
1400 |
011/0033 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
1680 |
6,4 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BHG P |
3000 |
2200 |
2000 |
011/0043 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
1400 |
14,9 |
| BHG PZ |
3700 |
3000 |
2700 |
011/0080 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
1400 |
14,9 |
| BHG M |
4500 |
3600 |
3200 |
011/0044 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
1400 |
14,9 |
| BHG G |
6000 |
4800 |
– |
011/0045 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
1400 |
14,9 |
|
| |
 |
|
hp internal gear pumps up to 40 bar (Direction D = direct - clockwise) |
Pump
Series
B
Size: |
Viscosity: 6 mm2 sec-1 at 20° C |
Gear
Rotor
Size
Ø |
Shaft
Ø |
Threaded
Connection
for (S/A) |
Mano-meter
Con-nection |
Heating
Capacity
H1 in Watt
at 220V, 50Hz
at I/D |
Initial
Pump
Breakaway
Torque
at I/D |
n = 1400 min-1
Discharge l/h |
n = 2800 min-1
Discharge l/h |
at
9 bar |
at
30 bar |
at
40 bar |
Article
No.
D |
at
9 bar |
at
30 bar |
at
40 bar |
Article
No. D |
| BP |
45 |
30 |
20 |
012/0002 |
90 |
60 |
50 |
014/0002 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| BM |
80 |
60 |
50 |
012/0003 |
160 |
130 |
120 |
014/0003 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| BG |
120 |
100 |
80 |
012/0004 |
240 |
200 |
190 |
014/0004 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| BF |
160 |
140 |
120 |
012/0005 |
320 |
270 |
260 |
014/0005 |
25 |
12 |
3/8" |
– |
100 |
1,2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BG PP |
150 |
100 |
80 |
012/0052 |
300 |
240 |
210 |
014/0052 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG PZ |
200 |
160 |
140 |
012/0053 |
400 |
310 |
280 |
014/0053 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG P |
300 |
240 |
200 |
012/0019 |
600 |
520 |
480 |
014/0019 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG MZ |
– |
– |
– |
– |
850 |
750 |
700 |
014/0068 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG M |
450 |
390 |
360 |
012/0020 |
900 |
800 |
730 |
014/0020 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG GZ |
– |
– |
– |
– |
1100 |
930 |
870 |
014/0054 |
38 |
12 |
½" |
– |
100 |
1,6 |
| BG G |
600 |
540 |
480 |
012/0021 |
– |
– |
– |
– |
38 |
12 |
½" |
– |
100 |
1,6 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BH P |
1000 |
700 |
600 |
012/0031 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
160 |
3,2 |
| BH M |
1500 |
1200 |
1000 |
012/0032 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
160 |
3,2 |
| BH G |
2000 |
1700 |
1400 |
012/0033 |
– |
– |
– |
– |
56 |
18 |
¾" |
¼" |
160 |
3,2 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BHG P |
3000 |
2200 |
2000 |
012/0043 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
280 |
4,6 |
| BHG PZ |
3700 |
3000 |
2700 |
012/0080 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
280 |
4,6 |
| BHG M |
4500 |
3600 |
3200 |
012/0044 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
280 |
4,6 |
| BHG G |
6000 |
4800 |
– |
012/0045 |
– |
– |
– |
– |
75 |
22 |
1 ½" |
– |
280 |
4,6 |
|
To insure proper pump functioning, all pipe connections must be sized as per the principles of fluid technology using the phase quantity and in accordance with the given conditions at the installation site!
The size of the pump and/or device connections is not indicative of the size of the pipe connection which must be used. |
 |
 |
 |
 |
 |
Gear
Rotor Size |
Discharge l/h |
a1 |
a2 |
a3 |
b1 |
c1 |
c2 |
c3 |
c4 |
c5 |
c6 |
c7 |
c8 |
d1 |
| 1400 min-1 |
2800 min-1 |
| 25 |
45 - 160 |
90 - 320 |
35,5 |
20 |
33 |
51 |
41,5 |
14 |
16 |
40 |
20 |
55,5 |
76 |
131,5 |
12 |
| 38 |
150 - 600 |
300 - 1100 |
43 |
26,5 |
38 |
70 |
55,5 |
14 |
16 |
40 |
20 |
69,5 |
76 |
145,5 |
12 |
| 56 |
1000 - 2000 |
– |
48,5 |
38 |
45 |
96 |
71,5 |
15 |
18 |
79 |
27 |
86,5 |
124 |
210,5 |
18 |
| 75 |
3000 - 6000 |
– |
64,5 |
83 |
70 |
115 |
129,5 |
18 |
25 |
65 |
37 |
147,5 |
127 |
274,5 |
22 |
|
 |
Gear
Rotor Size |
Discharge l/h |
sw |
e |
d2 |
d3 |
e1 |
e2 |
f2 |
f3 |
f4 |
g1 |
h1 |
h2 |
h3 |
| 1400 min-1 |
2800 min-1 |
| 25 |
45 - 160 |
90 - 320 |
27 |
31,2 |
54 |
80 |
G 3/8" |
71 |
16,5 |
38 |
92 |
43 |
11 |
13 |
13 |
| 38 |
150 - 600 |
300 - 1100 |
27 |
31,2 |
54 |
80 |
G ½" |
82 |
19 |
44 |
92 |
43 |
11 |
13 |
13 |
| 56 |
1000 - 2000 |
– |
46 |
53,1 |
60 |
100 |
G ¾" |
112 |
22,5 |
67 |
120 |
65 |
13 |
13 |
25 |
| 75 |
3000 - 6000 |
– |
55 |
63,5 |
80 |
120 |
G 1 ½" |
170 |
35 |
100 |
150 |
90 |
14,5 |
15 |
– |
|